H1Z2Z2-K

header edlersystems cable2 min v4
Solarkabel
H1Z2Z2-K

For freely movable use or fixed installation in photovoltaic systems in accordance with EN 60364-7-712. They may be used indoors, outdoors, in potentially explosive atmospheres, in industry or on farms. The cable is short-circuit and earth-fault proof.

Number of conductors x 
Nominal cross-section
Sheath color Conductor structure Outer Ø (min - max)
min - max
Weight Conductor resistance
at 20°C
Current carrying capacity
at 60°C in air
Cu count Central warehouse Factory warehouse
mm² approx. mm mm approx. kg/km ca. Ω/km A kg/km
1 x 2,5
50 x 0,25 4,7 - 5,1 45,0 8,2 41,0 25,0
1 x 4
56 x 0,31 5,2 - 5,6 55,0 5,1 55,0 40,0
1 x 6
80 x 0,31 5,7 - 6,1 75,0 3,4 70,0 60,0
1 x 10
80 x 0,41 6,8 - 7,7 115,0 2,0 98,0 100,0
1 x 10
80 x 0,41 6,8 - 7,7 115,0 2,0 98,0 100,0
1x 16
128 x 0,40 8,3 - 9,0 171,0 1,2 132,0 160,0
1x 16
128 x 0,40 8,3 - 9,0 171,0 1,2 132,0 160,0
1 x 25
200 x 0,40 10,0 - 10,7 273,0 0,795 176,0 250,0
1 x 35
280 x 0,40 11,1 - 12,2 364,0 0,565 218,0 350,0
1 x 50
400 x 0,40 12,6 -13,3 515,0 0,393 276,0 500,0
1 x 70
356 x 0,56 14,4 - 16,2 735,0 0,277 347,0 700,0
1 x 95
485 x 0,50 16,2 - 18,1 960,0 0,21 416,0 950,0
1 x 120
614 x 0,50 18,3 - 20,1 1.220,0 0,164 488,0 1.200,0

TÜV EN 50618
TÜV IEC 62930
TÜV 2 PfG 1169/10.19

  • cooper strand, tinned, fine-stranded accrding
    to DIN VDE 0295 Kl. 5, IEC 60228 cl. 5
  • Core isolation: cross-linked speciality polyolefin
  • Outer sheath: cross-linked speciality polyolefin UV-resistant
  • Sheath colour: black, red, blue

Special characteristics:

  • High water resistance
  • High insulation resistance
  • High mechanical stability
  • Optimised for floating PV systems
Nominal voltage U₀/U: 1/1 kV AC
1,5/1,5 kV DC
Test voltage: 6,5 kV AC
15 kV DC
Temperature range:
When laying: max. -25°C
Operating: -40°C to +90°C
Permissible operating temp. at conductor: max. +120°C
Short circuit temperature: max. +250°C/5 sec.
Minimum bending radius:
When laying: 10 x DA
Fixed laying: 4 x DA
Reaction to fire: Dca
Resistance against acid and alkaline solution: EN 60811-404
Ozone resistance: EN 50618
Halogen free: EN 50267-2-1
UV-stability: EN 50289-4-17