LiPC11Y

header edlersystems cable2 min v4
Motor-Positionsmeldeleitung
LiPC11Y

This cable is suitable for permanently flexible use and transmits control pulses for positioning and travel characteristics. Used as signalling and data cable, especially in drag chains. The shielding ensures excellent EMC properties. The notch-resistant and low-adhesion PUR outer sheath is characterised by very good oil resistance and good chemical resistance.

Download datasheet (LiPC11Y)
Number of conductors x 
Nominal cross-section
Outer Ø Weight Cu count Central warehouse Factory warehouse
mm² approx. mm approx. kg/km kg/km
4 x 2 x 0,25 + 2 x 1,0 8,8 112,0 91,0

based on System Indramat IN 209

  • Bare copper stranded wire, extra-fine stranded
    0,25 mm² = 19 x 0,127 mm      
    1 mm² = 126 x 0,10 mm
  • Polyolefin core insulation
  • Core labelling:
    0.25 mm²: brown/green/grey/pink/blue/purple/red/black
    1 mm²: white/brown
  • Fleece taping
  • Shielding made of tinned copper wires
  • PUR outer sheath
  • Sheath colour orange (RAL 2003)

Special properties:

  • halogen-free
  • flexible at low temperatures
  • abrasion resistant
  • oil resistant
Operating voltage U: max. 250 V
Testing voltage: 1500 V
Insulating resistance: ≥ 250 MOhm x km
Speed: max. 220 m/min
Acceleration: max. 10m/s²
Tensile strength:: max. 50 N/mm²
Temperature range:
When laying: max. 0°C
Operating temperature: -40°C to +80°C
Conductor operating temperature: max. +80°C
Short-circuit temperature: max. +150/5 sec.
Minimum bending radius: min. 90 mm
Fire behaviour: EN 60332-1-2
IEC 60332-1
Oil resistance: IEC 60811-404