H03VVH2-F

header edlersystems cable2 min v4
PVC-Schlauchleitungen
H03VVH2-F

Particularly suitable for light hand-held appliances with low mechanical loads and for connecting light electrical appliances such as household appliances, office machines, radios, etc., insofar as this is authorised in the relevant appliance regulations. Not approved for cooking or heating appliances. These cables are not suitable for use outdoors, in commercial and agricultural operations or for connecting commercial power tools.

Download datasheet (H03VVH2-F)
Number of conductors x 
Nominal cross-section
Sheath color Conductor Ø Insulation thickness External dimensions Weight Conductor resistance
at 20°C
Current carrying capacity
at 30°C
Cu count Central warehouse Factory warehouse
mm² approx. mm approx. mm approx. mm approx. kg/km ca. Ω/km A kg/km x x
2 x 0,75
1,1 0,5 3,8 x 6,3 35,0 26,0 6,0 15,0
2 x 0,75
1,1 0,5 3,8 x 6,3 35,0 26,0 6,0 15,0

DIN VDE 0285-525-2-11/HD 21.5.S3/ÖNORM E 8241

  • Bare copper stranded wire, finely stranded according to DIN VDE 0295 cl.5,
    IEC 60228 cl.5
  • PVC core insulation TI2
  • Core labelling according to HD 308 S2
  • Cores stranded in layers with optimum lay lengths
  • PVC outer sheath TM2
Nominal voltage U₀/U: 300/300 V
Testing voltage: 2000 V
Insulating resistance: ≥ 20 MOhm x km
Temperature range:
When laying: min. +5°C
Operating temperature: +5°C do +60°C
Conductor operating temperature: max. +60°C
Short-circuit temperature: max. +150°C/5 sec.
Minimum bending radius: 6 x DA
CPR performance class: Eca