PVC-Schlauchleitungen
A05VV-F

Particularly suitable for medium mechanical loads in households and offices, insofar as this is permitted in the relevant appliance regulations. These cables are not suitable for use outdoors, in commercial and agricultural operations or for connecting commercial power tools.

Download datasheet (H05VV-F)
Number of conductors x 
Nominal cross-section
Sheath color Conductor Ø Insulation thickness Outer Ø Weight Conductor resistance
at 20°C
Current carrying capacity
at 30°C
Cu count Central warehouse Central warehouse Factory warehouse Factory warehouse
mm² approx. mm approx. mm approx. mm approx. kg/km ca. Ω/km A kg/km G x G x
5 G 6
2,9 0,8 16,5 485,0 3,3 40,0 300,0
5 G 6
2,9 0,8 16,5 485,0 3,3 40,0 300,0
7 G 1
1,3 0,6 9,0 155,0 19,5 10,0 70,0
7 G 1
1,3 0,6 9,0 155,0 19,5 10,0 70,0
7 G 1,5
1,5 0,7 10,4 199,0 13,3 16,0 105,0
7 G 1,5
1,5 0,7 10,4 199,0 13,3 16,0 105,0
10 G 1,5
1,5 0,7 14,0 309,0 13,3 16,0 150,0
7 G 2,5
1,9 0,8 13,1 317,0 8,0 20,0 175,0

DIN VDE 0285-525-2-11/ÖNORM E 8241

  • Bare copper stranded wire, finely stranded according to DIN VDE 0295 cl.5,
    IEC 60228 cl.5
  • PVC- core insulation TI2
  • Core labelling according to HD 308 S2,
    From 7-core version black cores with numbers
  • Cores stranded in layers with optimum lay lengths
  • PVC- outer sheath TM2
Nominal voltage U₀/U: 300/500 V
Testing voltage: 2000 V
Insulating resistance: ≥ 20 MOhm x km
Temperature range:
When laying: min. +5°C
Operating temperature: +5°C to +60°C
Conductor operating temperature: max. +70°C
Short-circuit temperature: max. +150°C/5 sec.
Minimum bending radius:
When laying: 5 x DA
Fixed installation: 3 x DA
CPR performance class: Eca