L-YY(ZG)Y

header edlersystems cable2 min v4
Kran- und Hebezeugleitungen
L-YY(ZG)Y

As a tensile, movable connecting cable for mobile and fixed telecommunication systems above and below ground as well as in opencast and blind shafts. Blue cables for intrinsically safe systems comply with the BB 22 450 Mining Code.

Download datasheet (L-YY(ZG)Y)
Number of conductors x 
Nominal cross-section
Conductor structure Outer Ø Weight Conductor resistance Operating capacity 800Hz Cu count Central warehouse Factory warehouse
mm² approx. mm approx. mm approx. kg/km Ω/km max. nF/km kg/km
1 x 2 x 0,5 12 x 0,21 10,0 100,0 38,9 90,0 11,0
2 x 2 x 0,5 12 x 0,21 11,0 140,0 38,9 90,0 21,0
3 x 2 x 0,5 12 x 0,21 13,0 165,0 38,9 90,0 31,0
5 x 2 x 0,5 12 x 0,21 15,0 240,0 38,9 90,0 52,0
7 x 2 x 0,5 12 x 0,21 17,0 315,0 38,9 90,0 73,0
12 x 2 x 0,5 12 x 0,21 21,0 455,0 38,9 90,0 125,0
21 x 2 x 0,5 12 x 0,21 24,0 650,0 38,9 90,0 219,0
1 x 2 x 1,5 30 x 0,26 12,0 170,0 13,3 90,0 31,0
2 x 2 x 1,5 30 x 0,26 13,0 215,0 13,3 90,0 63,0
3 x 2 x 1,5 30 x 0,26 17,0 320,0 13,3 90,0 94,0

DIN VDE 0817

  • Bare copper stranded wire, fine stranded according to DIN VDE 0295 cl.5,
    IEC 60228 cl.5
  • PVC- core insulation
  • Cores with optimum lay lengths stranded in pairs.
    Pairs with optimum lay lengths stranded in layers
  • Core labelling in each layer Counting pair,
    black-blue, other pairs grey-blue,
    Single core 1.5 mm² green-yellow
  • PVC inner sheath
  • Strain relief: bundled aramid yarn
  • PVC-Aussenmantel
  • Sheath colour blue
Operating voltage U: 375 V
Testing voltage: 1000 V
Insulating resistance: ≥ 20 MOhm x km
Temperature range:
When laying: max. -5°C
Operating temperature: -55°C to +70°C
Conductor operating temperature: max. +70°C
Short-circuit temperature: +150°C/5 sec.
Minimum bending radius:
When laying: 10 x DA
Fixed installation: 5 x DA
Fire behaviour: EN 60332-1-2
IEC 60332-1