NSSHöu

header edlersystems cable2 min v4
Gummileitungen
NSSHöu

For very high mechanical loads in mining, open-cast mining, quarries, on construction sites for connecting heavy equipment and tools and in industry. Also suitable for fixed installation on plaster, in dry, damp and wet rooms. For a long service life under difficult operating conditions. However, not suitable for use on cable routing devices, reels and mobile cable carriers.

Download datasheet (NSSHöu)
Number of conductors x 
Nominal cross-section
Conductor Ø Outer Ø (min - max)
min - max
Weight Conductor resistance
at 20°C
Current carrying capacity
at 30°C
Cu count Central warehouse Central warehouse Factory warehouse Factory warehouse
mm² approx. mm mm approx. kg/km ca. Ω/km A kg/km G x G x
1 x 16 5,4 10,6 - 11,8 231,0 1,2 132,0 160,0
1 x 25 6,3 12,8 - 14,0 349,0 0,795 176,0 250,0
1 x 35 7,4 13,9 - 15,1 443,0 0,565 218,0 350,0
1 x 50 8,8 15,6 - 17,1 601,0 0,393 276,0 500,0
1 x 70 10,6 17,7 - 19,2 814,0 0,277 347,0 700,0
1 x 95 12,1 19,7 - 21,2 1.041,0 0,21 416,0 950,0
1 x 120 14,3 22,4 - 23,9 1.325,0 0,164 488,0 1.200,0
1 x 150 15,9 24,4 - 25,9 1.615,0 0,132 566,0 1.500,0
1 x 185 17,5 27,2 - 29,4 1.997,0 0,108 644,0 1.850,0
1 x 240 20,3 30,4 - 32,6 2.575,0 0,0817 775,0 2.400,0
3 G 1,5 1,6 11,1 - 12,7 195,0 13,7 23,0 45,0
3 G 2,5 1,9 12,2 - 13,8 235,0 8,2 30,0 75,0
3 G 70/35 10,6 42,3 - 45,3 3.714,0 0,277 250,0 2.450,0
3 G 95/50 12,1 48,1 - 52,1 5.899,0 0,21 301,0 3.350,0
3 G 120/70 14,2 54,6 - 58,6 6.482,0 0,164 352,0 4.300,0
3 G 150/70 16,1 60,0 - 64,0 7.568,0 0,132 404,0 5.200,0
4 G 1,5 1,6 11,8 - 13,1 205,0 13,7 23,0 60,0
4 G 2,5 1,9 14,1 - 16,1 319,0 8,2 30,0 100,0
4 G 4 2,4 15,7 - 17,7 411,0 5,1 41,0 160,0
4 G 6 2,9 16,9 - 18,9 508,0 3,4 53,0 240,0
4 G 10 3,9 21,1 - 23,1 803,0 2,0 74,0 400,0
4 G 16 5,4 25,2 - 28,2 1.181,0 1,2 99,0 640,0
4 G 25 6,3 29,8 - 32,8 1.721,0 0,795 131,0 1.000,0
4 G 35 7,5 32,7 - 35,7 2.176,0 0,565 162,0 1.400,0
4 G 50 8,8 38,1 - 41,1 3.022,0 0,393 202,0 2.000,0
4 G 70 10,6 42,1 - 45,1 3.939,0 0,277 250,0 2.800,0
4 G 95 12,1 48,2 - 52,2 5.335,0 0,21 301,0 3.800,0
4 G 120 14,2 54,6 - 58,6 6.758,0 0,164 352,0 4.800,0
4 G 150 16,1 60,8 - 64,8 8.021,0 0,132 404,0 6.000,0
5 G 1,5 1,6 12, 7 -14,3 250,0 13,7 23,0 75,0
5 G 2,5 1,9 15,2 - 17,2 363,0 8,2 30,0 125,0
5 G 4 2,4 17,0 - 19,0 482,0 5,1 41,0 200,0
5 G 6 2,9 19,1 - 21,1 633,0 3,4 53,0 300,0
5 G 10 3,9 23,0 - 25,0 956,0 2,0 74,0 500,0
5 G 16 5,4 27,4 - 30,4 1.396,0 1,2 99,0 800,0
5 G 25 6,3 32,4 - 35,4 2.051,0 0,795 131,0 1.250,0
5 G 35 7,5 36,9 - 39,9 2.743,0 0,565 162,0 1.750,0
7 G 1,5 1,6 15,2 - 17,2 364,0 13,7 15,0 105,0
7 G 2,5 1,9 17,4 - 19,4 497,0 8,2 19,5 175,0
10 G 1,5 1,6 17,7 -19,7 476,0 13,7 12,7 150,0
12 G 2,5 1,9 21,2 - 23,2 735,0 8,2 15,6 300,0
18 G 2,5 1,9 24,5 - 27,5 1.034,0 8,2 13,5 450,0

DIN VDE 0250-812

  • Bare copper stranded wire, fine stranded according to DIN VDE 0295 cl.5,
    IEC 60228 cl.5
  • Rubber core isolation EPR 3GI3
  • Core labelling according to HD 308 S2
    from 7-core version black with numbers
  • Cores stranded in layers with optimum lay lengths
  • Rubber intersheath
  • Polychloroprene outer sheath 5GM5
    high abrasion resistance, oil resistant
  • Sheath colour yellow
Nominal voltage U₀/U: 0,6/1 KV
Testing voltage: 3000 V
Insulating resistance: ≥ 20 MOhm x km
Temperature range:
When laying: max. -25°C
Operating temperature: -40°C to +80°C
Conductor operating temperature: max. +80°C
Short-circuit temperature: max. +250°C/5 sec.
Minimum bending radius:
When laying: 4 x DA
Fixed installation: 10 x DA
Fire behaviour: EN 60332-1-2
IEC 60332-1
Oil resistance: DIN VDE 0473-811-404
EN 60811-404