H05BQ-F

header edlersystems cable2 min v4
Baustellen- und Purleitungen
H05BQ-F

In dry and damp rooms as well as outdoors for short periods under medium mechanical stress. As a tool connection cable with high oil resistance, abrasion resistance and notch resistance.

Download datasheet (H05BQ-F / H07BQ-F)
Number of conductors x 
Nominal cross-section
Conductor structure Insulation thickness Outer Ø (min - max)
min - max
Conductor resistance
at 20°C
Current carrying capacity
at 30°C
Cu count Central warehouse Central warehouse Factory warehouse Factory warehouse
mm² approx. mm approx. mm mm ca. Ω/km A kg/km G x G x
2 x 0,75 24 x 0,21 0,6 5,7 - 7,4 26,0 6,0 15,0
3 G 0,75 24 x 0,21 0,6 6,2 - 8,1 26,0 6,0 22,5
4 G 0,75 24 x 0,21 0,6 6,8 - 8,8 26,0 6,0 30,0
5 G 0,75 24 x 0,21 0,6 7,6 - 9,9 26,0 6,0 37,5
2 x 1 32 x 0,21 0,6 6,1 - 8,0 19,5 10,0 20,0
3 G 1 32 x 0,21 0,6 6,5 - 8,5 19,5 10,0 30,0
4 G 1 32 x 0,21 0,6 7,1 - 9,3 19,5 10,0 40,0
5 G 1 32 x 0,21 0,6 8,0 - 10,3 19,5 10,0 50,0

DIN VDE 0285-525-2-21
except X07BQ-F based on DIN VDE 0285-525-2-21

  • Bare copper stranded wire, fine stranded according to DIN VDE 0295 cl.5,
    IEC 60228 cl.5
  • Rubber core insulation, EI6
  • Core labelling according to HD 308 S2
    from 7-core version black with numbers
  • Cores stranded in layers with optimum lay lengths
    (inner protective sheath permissible)
  • PUR – outer sheath TMPU
  • Sheath colour orange (RAL 2003)

Special properties:

  • abrasion resistant
  • notch resistant
  • tear and cut resistant
Nominal voltage U₀/U:
H05BQ-F: 300/500 V
H07BQ-F: 450/750 V
Conductor operating temperature: max. +90°C
Testing voltage:
H05BQ-F: 2000 V
H07BQ-F: 2500 V
Temperature range:
When laying: max. -40°C
Operating temperature: -40°C to +80°C
Short-circuit temperature: max. 200°C/5 sec.
Minimum bending radius:
When laying: 5 x DA
Fixed installation: 3 x DA
Fire behaviour:
H05BQ-F: EN 60332-1-2
IEC 60332-1
CPR performance class:
H07BQ-F: Eca