F-vYDvY

header edlersystems cable2 min v4
Fernmeldekabel zur Innenverlegung
F-vYDvY

As data transmission cable in telecommunication systems and as modem cable inside buildings in dry on, in and under plaster.

Download datasheet (F-vYDvY)
Number of conductors x 
Nominal cross-section
Number of conductors x 
Nominal cross-section
Outer Ø Weight Cu count Central warehouse
mm² mm approx. mm approx. kg/km kg/km
4 x 0,5/1 4 x 0,5/1 4,0 31,0 21,0

based on ÖVE K 50

  • Copper wire, tinned, solid
  • PVC - core insulation
  • Cores twisted into fours
  • Core labelling according to ÖVE K 35
  • Banding made of plastic foil
  • Twist shield made of tinned copper wires
  • PVC outer sheath
  • Sheath colour yellow
Operating voltage U: max. 300 V
Testing voltage: 500 V
Impedance (0,1-2 Mhz): 850 Ohm
Operating capacity: max. 120 nF/km
Capacitive coupling (at 800 Hz): max. 500 pF/ 100m
Conductor resistance: 98 Ohm/km
Temperature range:
When laying: max. -5°C
Operating temperature: -30°C to +70°C
Minimum bending radius: 7,5 x DA
Fire behaviour: EN 60332-1-2
IEC 60332-1