F-2YJA2Y

header edlersystems cable2 min v4
Fernmeldekabel zur Außenverlegung
F-2YJA2Y

Outdoor telephone cables at local level for private branch exchanges, as well as connection cables in operating and industrial plants, in the ground, in cable ducts and cable conduits, and for indoor installation. The stranding cavities are continuously filled with petrolatum (F). The black PE outer sheath is UV-resistant. The polyethylene material (PE 2Y) is halogen-free. This cable is not approved for heavy current installations.

Download datasheet (F-2YJA2Y)
Number of conductors x 
Nominal cross-section
Sheath thickness Outer Ø Weight Cu count Central warehouse
mm approx. mm approx. mm approx. kg/km kg/km
6 x 2 x 0,6 1,8 11,5 115,0 36,0
10 x 2 x 0,6 1,8 13,0 173,0 59,0
20 x 2 x 0,6 1,8 16,0 305,0 115,0
30 x 2 x 0,6 1,8 19,0 398,0 172,0
50 x 2 x 0,6 1,8 23,0 595,0 285,0
100 x 2 x 0,6 2,0 31,0 1.187,0 568,0
6 x 2 x 0,8 1,8 12,9 184,0 62,0
10 x 2 x 0,8 1,8 15,0 237,0 103,0
20 x 2 x 0,8 1,8 19,4 451,0 203,0
30 x 2 x 0,8 1,8 21,8 599,0 304,0
50 x 2 x 0,8 2,0 26,2 930,0 504,0
60 x 2 x 0,8 2,0 30,5 1.177,0 606,0

based on the Telekom Austria standard

  • Bare copper wire, solid Ø 0,6 mm and Ø 0,8 mm
  • PE - core insulation
  • Core labelling according to the Telekom Austria standard
  • Cores stranded into star quads and these in layers
  • Cavities continuously filled with petrolatum
    (longitudinally watertight)
  • Strapping made of plastic film
  • Outer sheath as a layered sheath,
    plastic-coated aluminium tape
    welded to PE jacket
  • Sheath colour black
Operating voltage U: max. 200 V
Testing voltage at 50 Hz:
Core/Core: 500 V
Core/Shield: 2000 V
Insulating resistance: 5 GOhm x km
Capacitive coupling (at 800 Hz): max. 300 pF/ 100m
Conductor resistance of the loop:
Ø 0,6 mm: max. 130 Ohm/km
Ø 0,8 mm: max. 73,2 Ohm/km
Operating capacity (at 800 Hz): max. 52 nF/km
Temperature range:
When laying: max. -20°C
Operating temperature: -20°C to +80°C
Minimum bending radius: 10 x DA
CPR performance class: Fca