A-2Y(L)2Y

header edlersystems cable2 min v4
Fernmeldekabel zur Außenverlegung
A-2Y(L)2Y

Outdoor telephone cable at local level for private branch exchanges, as well as a connection cable in operating and industrial systems, in the ground, in cable ducts and cable conduits, and for indoor installation. PE copolymer-coated aluminium tape (L) on both sides, which is permanently bonded to the PE outer sheath (2Y), guarantees water vapour resistance and transverse watertightness. The black PE outer jacket is UV-resistant. The polyethylene material (PE 2Y) is halogen-free. Not approved for high voltage installations.

Download datasheet (A-2Y(L)2Y)
Number of conductors x 
Nominal cross-section
Sheath thickness Outer Ø Weight Cu count Central warehouse Factory warehouse
mm approx. mm approx. mm approx. kg/km kg/km
2 x 2 x 0,6 1,8 8,1 60,0 13,0
4 x 2 x 0,6 1,8 10,0 85,0 24,0
6 x 2 x 0,6 1,8 10,3 103,0 36,0
10 x 2 x 0,6 1,8 11,5 135,0 59,0
20 x 2 x 0,6 1,8 15,2 225,0 115,0
30 x 2 x 0,6 1,8 16,6 320,0 172,0
40 x 2 x 0,6 1,8 18,0 398,0 228,0
50 x 2 x 0,6 1,8 19,4 465,0 285,0
70 x 2 x 0,6 2,0 22,8 600,0 413,0
100 x 2 x 0,6 2,0 27,9 830,0 568,0
150 x 2 x 0,6 2,2 33,2 1.220,0 884,0
200 x 2 x 0,6 2,2 36,4 1.600,0 1.178,0
2 x 2 x 0,8 1,8 8,6 74,0 22,0
4 x 2 x 0,8 1,8 10,9 115,0 41,0
6 x 2 x 0,8 1,8 11,3 140,0 62,0
10 x 2 x 0,8 1,8 13,2 195,0 103,0
20 x 2 x 0,8 1,8 17,3 335,0 203,0
30 x 2 x 0,8 1,8 19,0 475,0 315,0
40 x 2 x 0,8 2,0 20,7 595,0 404,0
50 x 2 x 0,8 2,0 23,7 730,0 505,0
70 x 2 x 0,8 2,0 25,3 970,0 734,0
100 x 2 x 0,8 2,2 32,2 1.375,0 1.047,0
150 x 2 x 0,8 2,2 37,7 2.020,0 1.571,0
200 x 2 x 0,8 2,6 42,3 2.610,0 2.095,0

DIN VDE 0816

  • Bare copper wire, solid Ø 0,6 mm and Ø 0,8 mm
  • PE - core insulation 2YI1
  • Core labelling of a quad is carried out
    by black rings
  • 4 cores to form a star quad, stranded
    5 fours to form a bundle, bundle in layers
  • Strapping made from plastic film
  • Outer jacket as a layered jacket,
    plastic-coated aluminium strip with
    PE sheath (2YM1) welded together
  • Sheath colour black
Operating voltage U: max. 225 V
Testing voltage (50 Hz 2 min.):
Core/Core: 500 V
Core/Shield: 2000 V
Insulating resistance: 5 GOhm x km
Conductor resistance of the loop:
Ø 0,6 mm: max. 130 Ohm/km
Ø 0,8 mm: max. 73,2 Ohm/km
Operating capacity (at 800 Hz)
Ø 0,6 mm: max. 50 nF/km
Ø 0,8 mm: max. 55 nF/km
Temperature range:
Bei Verlegung: max. -20°C
Operating temperature: -20°C to +70°C
Minimum bending radius: 10 x DA
CPR performance class: Fca