Profinet UL / CSA, SK

header edlersystems cable2 min v4
Busleitungen
Profinet UL / CSA, SK

Data cable with transmission rates of up to 100 Mbits/s, especially for industrial secondary and tertiary cabling. Type A for fixed installation, type B for limited flexible use, type C for highly flexible use (drag chain). The cable is manufactured in the installation-friendly quick contact version (SK). TypeC is equipped with a robust polyurethane sheath.

Download datasheet (Profinet UL / CSA, SK)
Number of conductors x 
Nominal cross-section
Outer Ø Weight Cu count Central warehouse Factory warehouse
mm approx. mm approx. kg/km kg/km
Typ A 2 x 2 x 0,64 6,5 67,0 33,0
Typ B 2 x 2 x 0,38 mm² 6,5 67,0 33,0
Typ C 2 x 2 x 0,38 mm² 6,5 61,0 33,0

Profinet Draft

  • Typ A: Bare copper wire
  • Type B: copper strands, 7-wire tinned
  • Type C: copper strands, 19-wire tinned
  • Polyolefin core insulation
  • Core colours: white, yellow, blue, orange
  • Star quad
  • Intermediate cover
  • Overall shield made of aluminium-laminated foil and braid
    made of tinned copper wires
  • Type A and B: PVC outer sheath
  • Type C: PUR outer sheath
  • Sheath colour green (RAL 6018)
Characteristic impedance: 100 Ohm ± 15 %
Insulating resistance: ≥ 5 GOhm x km
Operating capacity (at 1kHz): 48 nF/km
Loop resistance (except Type C): max. 115 Ohm/km
max. 110,8 Ohm/km
Temperature range:
Typ A -40°C to +80°C
Typ B -10°C to +70°C
Typ C -30°C to +70°C
Minimum bending radius:
Typ A/B/C 100 mm/46 mm/50 mm
Fire behaviour Type A and Type B: IEC 60332-3
c(UL) listing CMG UL 444
UL listing PLTC UL 13
c(RU)us Recognition AWM style 20201
Fire behaviour Type C: IEC 60332-1
c(UL)us listing CMX UL 444