The cable can be used as a connecting cable in general mechanical engineering. It is used as a connecting cable between bus segments. The advantage of bus technology lies in the cost-effective wiring of machines and systems. Only the component for which the information is intended reacts to the signal and processes it. The shielding ensures use in EMC-critical environments. Suitable for fixed installation in dry rooms.

Download datasheet (Profibus SK - Quick contact FRNC - halogen-free)
Number of conductors x 
Nominal cross-section
Outer Ø Weight Cu count Central warehouse Factory warehouse
mm approx. mm approx. kg/km kg/km
02YH(St)CH 1 x 2 x 0,64 8,0 75,0 27,0

DIN VDE 19245 T3 and EN 50170

  • Bare copper wire, solid, Ø 0,64 mm
  • Cell PE core insulation, halogen-free
  • Core colours red and green
  • Cores stranded in layers with optimum lay lengths
  • Halogen-free intermediate sheath (SK)
  • Overall shield made of aluminium-laminated foil and braiding
    of tinned copper wires
  • Halogen-free outer sheath
  • Sheath colour violet (RAL 4001)
Characteristic impedance: 150 Ohm ±- 10%
Conductor resistance: max. 57,1 Ohm/km
Loop resistance: max. 110 Ohm/km
Insulating resistance: ≥ 1 GOhm x km
Operating capacity (at 1kHz): max. 28 nF/km
Attenuation for:
9,6 kHz: max. 2,5 dB/km
38,4 kHz: max. 4,0 dB/km
4,0 MHz: max. 22 dB/km
16 MHz: max. 42 dB/km
Temperature range:
When laying: max. -5°C
Operating temperature: -25°C to +60°C
Minimum bending radius: 150 mm
CPR performance class: Fca
Corrosiveness of fire gases: EN 60754-2
IEC 60754-2